Toa VM-3000 Series User Manual

Page 113

Advertising
background image

113

To VM-3240VA/3360VA’s
RM1 LINK IN or RM2 LINK
IN connector

RM-300MF bottom

Wall mount bracket unit
(supplied with the RM-300MF)

Terminal block

9 mm

25 mm

(+)

(–)

Connection cable
(with RJ45 connectors)

VX-2000DS’
DC POWER OUT terminal

AC adapter AD-246 or equivalent unit

AC adapter AD-246

Cut off the DC plug of the AD-246 AC Adapter,
and treat the tip of cable as follows.

1

2

3

4

5

6

7

8

(Use when no back up power supply
is required.)

(–)

(+)

Cut off

When a STP Category 5 straight cable is used as communication cable (excluding power line) between the
RM-300MF and the VM-3240VA or VM-3360VA, the maximum cable distance in a system is 800 m in total.

The maximum distance of power cable between the RM-300MF and the VX-2000DS is as follows.

The following table shows the maximum cable distance when STP Category 5 straight cable (with RJ45
connectors) is used.

No. of expansion units

RM-300MF alone

Cable

STP Category 5

140 m

100 m

80 m

60 m

RM-300MF +
RM-320F x 1

RM-300MF +
RM-320F x 2

RM-300MF +
RM-320F x 3

To make longer cable lengths than those shown in the above table, use over 4-pair shielded CPEV cable.
The relationship of the CPEV cable conductor diameter to the maximum cable distance is as follows:

No. of expansion units

RM-300MF alone

Conductor diameter

ø0.65 mm

230 m

ø0.9 mm

460 m

ø1.2 mm

800 m

170 m

130 m

330 m

260 m

570 m

450 m

90 m

200 m

350 m

RM-300MF +
RM-320F x 1

RM-300MF +
RM-320F x 2

RM-300MF +
RM-320F x 3

[When power is supplied from the VX-2000DS or AC adapter]

* Usable AC adapter

24 V DC/over 200 mA (Operation range: 14 – 28 V DC)
Usable power input plug: Non-polarity type

(5.5 mm outer diameter, 2.1 mm inner diameter, and 9.5 mm long)