99

RM-200M

Linkage Bracket B

3

2

Extension cable
(supplied with the RM-210)

RM-210

Linkage Bracket A

[Bottom]

[Bottom]

RM-210

RM-200M

4

Linkage Bracket A ...................................................... 2 (supplied with the RM-210)
Linkage Bracket B ...................................................... 1 (supplied with the RM-210)
Tapping screw 3 x 8 ................................................. 12 (supplied with the RM-210)
Extension cable.......................................................... 1 (supplied with the RM-210)

13.5. Linking the RM-200M with the RM-210 (For Desktop Mounting)

To expand the RM-200M by adding the RM-210 Remote Microphone Extension unit, use the parts supplied
with the RM-210 shown below to link the 2 units.
Complete the DIP switch settings in advance, then follow the procedure below to link both units.

Step 1. Turn over both the RM-200M and the RM-210, and keep them in close contact with each other.

Step 2. Connect the extension cable supplied with the RM-210 between both extension connectors on the

RM-200M’s side and the RM-210’s side.

Step 3. Using the Linkage Bracket B and 4 screws (indicated by arrows in the figure) supplied with the RM-

210, link both units together.

Step 4. Using the 2 Linkage Brackets A and 8 screws (indicated by arrows in the figure) supplied with the RM-

210, fix both units securely.

Note
Use the same steps above when another RM-210 is added.

Notes
• As the Linkage Bracket A has 2 spare

screw holes, use them to link both units if
the designated screw threaded holes are
damaged.

• If incorrect or loose cable connection is

found between both units, remove all the
bracket fixing screws to disassemble the
units and reconnect the cable connection
correctly. Then, link the units again with
the screws.