92

Wall mount bracket unit for the RM-300MF ................................. 1 (supplied with the RM-300MF)
Tapping screw 4 x 25 (for wooden wall mounting) ...................... 2 (supplied with the RM-300MF)

13. INSTALLATION

13.1. Installing the RM-300MF on a Wall

To mount the RM-300MF on the wall, the following parts are required.

• Install the unit only in a location that can structurally support the weight of the unit and the

mounting bracket. Doing otherwise may result in the unit falling down and causing personal
injury and/or property damage.

• Be sure to install the bracket on the wall using 2 screws.

WARNING

Wall mount bracket unit
(supplied with the RM-300MF)

RM-300MF

46

100

92

ø4.5

3-4.5 x 6.5

RM-300MF's center line

83.5

107.6

215

ø60

Wall mount bracket unit for the RM-300MF

Use 2 mounting holes indicated by
arrows to secure the bracket unit.

Wall mount bracket unit's center line

9.7

Unit: mm

Step 1. Install the wall mount bracket unit supplied with the RM-300MF on the wall.

Install the unit on the wall using 2 screws.
The RM-300MF comes with 2 tapping screws (4 x 25) for direct wall mounting.
However, if these supplied screws are not appropriate for the mounting, prepare appropriate ones
separately.