Toa VM-3000 Series User Manual

Page 12

Advertising
background image

12

17. VM Reset Key

For the VM-3240VA and VM-3360VA:
Resets the entire system.
For the VM-3240E and VM-3360E:
Resets only VM-3240E or VM-3360E Extension
amplifiers.

18. Level Meter

Indicates the output level of the unit’s internal
amplifier.

19. Emergency Microphone

Only used while in emergency broadcast mode.
Press the Talk key located on the side of the
microphone to broadcast emergency
announcements.

20. Monitor Speaker

Buzzer tone is audible from this speaker when
the emergency mode is activated by external
equipment other than the unit’s Emergency
Activation switch (5) or when any failure occurs.

21. Emergency Microphone Indicator (red)

Lights when the unit’s front panel-mounted
emergency microphone (19) is used.

22. Emergency Microphone Volume Control

Rotate clockwise to increase the emergency
microphone volume.
Rotate counterclockwise to decrease the
emergency microphone volume.

23. Reset Key [RESET]

For emergency broadcasts:
Terminates the emergency broadcast and
returns operation to the original general
broadcast.
For general broadcasts:
Resets the front panel’s output selection status.

24. Alert Announcement Start Key [ALERT]

For emergency broadcasts:
Plays recorded Alert announcements through the
speaker output selected with the Output
Selection key (33). Holding down this key for 3
seconds stops the broadcast.
For general broadcasts:
Used to test LED indicators. (While pressed,
LED indicators remain lit and the unit’s internal
buzzer sounds.)

25. Alert Announcement Indicator (red)

Remains lit while a recorded Alert announcement
is being broadcast.

26. Failure Indicator (yellow) [GENERAL FAULT]

(VM-3240VA and VM-3360VA only)

Flashes when a failure occurs while sounding the
internal buzzer. Pressing the [OK] key (7) stops
the buzzer and switches the indicator from
flashing to steady ON. Failure details are
displayed on the LCD (11). (When there are
multiple failures, they can be checked by moving
the screen using the [+] key (10) or [–] key (8)).
Failures are not displayed on the LCD when in
setting mode. Failures are displayed or notified
after exiting the setting mode. Also, if any failure
occurs during general or emergency broadcasts,
the operation status and failure display are
alternately shown on the LCD.

27. CPU Failure Indicator (yellow) [CPU FAULT]

Lights when the CPU fails.

28. All-Zone Call Selection Key [ALL]

Simultaneously selects all speaker outputs for
general and emergency broadcasts. Press again
to reset the simultaneous selection.
When pressed, all speaker output volume
controls do not work in both general and
emergency broadcast modes.

29. All-Zone Call Indicator (green) [ALL]

Lights when an all-zone call is initiated.

30. Speaker Output Volume Controls [OUTPUT 1 – 6]

Adjust the output volume of speaker outputs 1 – 6.

31. Emergency Broadcast Output Indicators (red)

[EMERGENCY]

Indicate the speaker outputs for emergency
broadcasts.

32. Selected Output Indicators (green) [SELECT]

Indicate the speaker outputs selected with the
Output Selection key (33).

33. Output Selection Keys

Select corresponding speaker output.
Press again to reset the selection.
For general broadcasts:
Select and reset broadcast zones.
For emergency broadcast:
Select and reset speaker outputs for emergency
broadcasts made by the unit’s front panel-
mounted emergency microphone and automatic
announcements.

34. Communications Failure Indicator (yellow)

[COM FAULT]

(VM-3240E and VM-3360E only)
Flashes when failures are detected in
communications with the VM-3240VA or VM-
3360VA.