Cpu off function, What is the cpu off function, Making all-zone calls using the cpu off function – Toa VM-3000 Series User Manual

Page 47: Making all-zone calls from the rm-300mf, Using the cpu off function

Advertising
background image

47

9.1. What Is the CPU OFF Function?

The CPU OFF function bypasses the CPU*, which the VM-3000 system uses in ordinary broadcasts, and
allows all-zone calls to be made from the VM-3360VA or VM-3240VA or RM-300MF. Use this function when
ordinary broadcasts cannot be made due to system failures, etc.

* A signal processing unit installed in the VM-3240VA, VM-3360VA, VM-3240E, or VM-3360E and RM-300MF.

9.2. Making All-Zone Calls Using the CPU OFF Function

9.2.1. Making all-zone calls from the VM-3240VA or VM-3360VA

While the Emergency Activation switch on the front panel of the VM-
3360VA or VM-3240VA and the Emergency Microphone’s Talk key
are simultaneously held down, the Emergency indicator (red)
remains lit and the amplifier is placed in CPU OFF condition,
allowing all-zone calls to be made from the Emergency Microphone.
Adjust the sound volume with the Emergency Microphone’s volume
control.

9.2.2. Making all-zone calls from the RM-300MF using the CPU OFF function

Set DIP switch 8 on the RM-300MF’s bottom surface to the ON position to use the CPU OFF function. Setting
the RM-300MF’s front-mounted CPU ON/OFF switch to the OFF position causes the CPU OFF indicator to
light red, placing the unit in CPU OFF mode. Pressing the Emergency Microphone’s Talk key allows all-zone
calls to be made from the Emergency Microphone. Adjust the sound volume with the microphone volume
control.

9. CPU OFF FUNCTION

MIC

SP

CPU

OFF

ON

CPU ON/OFF

switch

Microphone volume control

CPU OFF indicator

Talk key

OFF

ON

[RM-300MF front]

[RM-300MF rear]

1
2

ON

3
4
5
6
7
8

DIP switch

Emergency microphone volume control

Emergency microphone

Emergency Activation switch/Emergency indicator

[VM-3240VA/3360VA]

EMERGENCY

Talk key

Advertising