4.6. RM-210 Remote Microphone Extension

The RM-210 is an expansion unit for the RM-200M Remote Microphone. Up to 4 Expansion Units can be
added, expanding the available function keys to up to 10 per unit. Zone selection or automatic announcement
start functions can be assigned to each function key using the dedicated software. Only the right-side
indicators are used.

1. Indication Label Holder

Write the name, purpose, etc. of the indicator
and key on a label and insert the label into the
holder from the top. Labels can be printed using
the setting software. (For more information, refer
to "Printing Remote Microphone Labels" in the
separate software manual.)

2. Not used.

3. Broadcast Zone / Automatic Announcement

Start Indicators (green)

Indicator’s function assigned to each indicator is
determined by software settings.
Broadcast Zone Indicators
Light when their corresponding zones are
selected.
Automatic general broadcast Announcement
Start Indicators
Light when an automatic announcement is
started.

4. Broadcast Zone Selector Keys/ Automatic

Announcement Start Keys

Key function assigned to each key is determined
by software settings.

Broadcast Zone Selector Keys
Select broadcast zones. Pressing the RM-200M
Remote Microphone’s Talk key (7) after zone
selection allows microphone announcements to
be broadcast over the selected zone(s).
Automatic general broadcast Announcement
Start Key
Automatic general broadcast announcements
are broadcast over the selected zone(s).

5. Connector [Extension]

Connect the RM-200M Remote Microphone or
additional RM-210 Remote Microphone
Extension to this connector.
The same terminal is provided on the other side
as well.