119

RU-2002 Remote unit

AWG 28 – 22

VM-3240VA/3360VA rear

OUTPUT

REMOTE

DC IN

12 / 24 V

DC IN

12 V

H

C

E

E

C

H

PBX, main telephone device, etc.

Control signal

Audio signal

E C H

When using a single-core shielded
cable, connect the shielded mesh to
both E and C terminals.

Telephone line

* Prepare the switch assembly locally at your end.

Press-to-talk switch box*
(Remote switch)

AWG 28 – 22

AWG 28 – 22

14.4.3. Example of connection to external equipment