The only electrical input connections to the dryer are the 3-phase (30) power leads (L1,L2,L3 and

sometimes neutral) and ground. Single-phase (1 0) power for the control circuit is done internally to

the dryer. No single-phase (10) input connection is required on a 3-phase (30) dryer.

1) GAS MODELS and STEAM MODELS ONLY

For gas and steam dryers manufactured for operation at 3-phase (30), the electrical connections are
made at the power distribution block located in the service box at the rear, upper left comer of the
dryer. The ground connection is made to the copper lug also provided in this box. To gain access to
the service box contactor, the service box cover must be removed.

23