I. № heat)...no voltage at heating unit (i.e, Hot surface ignition [hsi] module, Electric oven contactor, or – ADC AD-78 User Manual

Page 65: Steam damper system pneumatic solenoid)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

I.

№ heat)...no voltage at heating unit (i.e.,

Gas M odel -

Hot Surface Ignition [HSI] module,

Electric Model

- electric oven contactor, or

Steam M odel -

steam damper system pneumatic

solenoid) •••

GAS MODELS...

1. Fault in hot surface ignition system ...

a. H ot surface ignitor glows but no ignition and H SI m odule "LOC KS-O UT" ("red" L.E.D. [light

em itting diode] indicator flashes)...

1) Flam e probe assem bly is out of adjustm ent or has failed.

2) Severe air turbulence.

3) Failed H SI m odule.

4) Failed gas valve.

b. H ot surface ignitor glows, but burner goes off right away ...

1) Flam e probe assem bly is out of adjustm ent or has failed.

2) Sail switch is fluttering ...

a) Lint screen is dirty.

b) Restriction in exhaust duct work.

c. H ot surface ignitor does not glow and H SI m odule "LO CK S-O UT" ("red" L.E.D. indicator flashes) ...

1) Fault in hot surface ignitor wiring...break or loose connection.

2) Failed hot surface ignitor.

3) Failed H SI m odule.

ELECTRIC MODELS...

1. Fm led oven contactor/coil.

2. Failed electric heating elem ent(s).

STEAM MODELS...

1. Air O perated System ...

a. No (external) com pressed air f80

PSl required)

to steam dam per solenoid.

b. Failed steam dam per pneum atic solenoid.

60