e. Open main door. The dryer must stop and ALL indicator lights on the back side of the micro­

processor (computer) board must go out. (Refer to illustration on the previous page [page 681.)

f. Try to restart the dryer with the main door open.

g. The microprocessor (computer) board's L.E.D. display must read “DOOR."

h. Close the main door and restart the dryer.

i. Functional check of microprocessor (computer) board is complete.

2. Hot Surface Ignition (HSI) System

a. Upon completing installation of the replacement

Hot Surface Ignition (HSI) module, reestablish
power to the dryer.

b. The HSI module's "red" indicator light will light

for up to approximately 5 seconds (self check
routine).

If the HSI module's "red" indicator light stays
on or flashes continuously, then the HSI module
is wired incorrectly or has failed.

O

RED INDICATOR LIGHT

DIAGNOSTIC ««ICATOR

LED

MODE

On

Control Fault

Z Flaahoi Plamo, No Cal for Heal
3 Ptashea Ignition Lockout

A

catalog Number; TRITON 2466H
Automatic Ignition System
Prepurge: 0 Sec., Ignition: 7.0 Sec.
Interpurge; 15 Sec.

Input: 24 VAC, 50/60 Hz., 000 mA
Valve; 24 VAC. 2.0 A max.
Ignitor: 24 VAC, or 120 VAC. 5.0 A max.

Ambient: -40*F to +180*F
ANSI Z21.20 CAN/C8A-C22.2 No. 199-M89

CAUTION; HI VOLTAQE DISCONNECT WIRINQ BEFORE SERVIOINQ

FC1

FC2

81 LI L2 82

W

o

o

1 1 1 1

1 1 1

O

c. Start the drying cycle.

d. The hot surface ignitor will turn on, and a few seconds later the gas valve will be energized. After

approximately 4 seconds the hot surface ignitor will shut off. Ignition (flame) should now be
established.

e. With the burner flame on, remove the flame sensor wire from the S2 terminal of the HSI module.

The burner flame must shut off immediately.

f. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

g. The hot surface ignitor will turn on, and after a few seconds later the gas valve will be energized

and the hot surface ignitor will shut off. Ignition (flame) should be evident for approximately
7 seconds and then shut off.

h. The HSI module will attempt two (2) additional ignition trials after which the HSI module will lock

out and the "red" indicator light will flash continuously.

i. Functional check of the Hot Surface Ignition (HSI) Module is complete.

1) Replace the flame sensor wire from the S2 terminal to the HSI module.

69