Section vi, Routine maintenance – ADC AD-78 User Manual

Page 48

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION VI

ROUTINE MAINTENANCE

A. CLEANING

A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from
various areas of the dryer, as well as throughout the duct work system. The frequency of cleaning
can best be determined from experience at each location. Maximum operating efficiency is dependent
upon proper air circulation. The accumulation of lint can restrict this air flow. If the guidelines in this

section are met, an ADC dryer will provide may years of efficient, trouble-free, and - most importantly -
safe operation.

WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE

ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE
HAZARD.

WARNING: KEEP DRYER AREA CLEAR AND FREE FROM COMBUSTIBLE

MATERIALS, GASOLINE, and OTHER FLAMMABLE VAPORS and
LIQUIDS.

NOTE:

Suggested time intervals shown are for average usage which is considered six (6) to eight

(8) operational (running) hours per day.

SUGGESTED CLEANING SCHEDULE

EVERY THIRD or FOURTH LOAD

Clean the lint screen every third or fourth load. A clogged lint screen will cause poor dryer performance. The
lint screen is located behind the lint door in the base of the dryer. Open the lint door, brush the lint off of the
lint screen, and remove the lint. Inspect the lint screen and replace if tom.

NOTE:

The frequency of cleaning the lint screens can best be determined from experience at

each location.

WEEKLY

Clean lint accumulation from the lint chamber, thermostat, and microprocessor temperature sensor
(sensor bracket) area.

WARNING: TO AVOID HAZARD OF ELECTRICAL SHOCK, DISCONTINUE

ELECTRICAL POWER SUPPLY TO THE DRYER.

43