Type of gas – ADC AD-78 User Manual

Page 31

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

2. Technical Gas Data

a. Gas Specifications

Type of Gas

Natural Gas

Liquid Propane Gas

Manifold Pressure*

3.5 - 4.0 inches W.C.

10.5 -11.0 inches W.C.

Inline Pressure

6.0-12.0 inches W.C.

11.0 inches W.C.

* Measured at the gas valve pressure tap when the gas valve is on.

b. Gas Connections:

Inlet connection-----------3/4-inch N.P.T.
Inlet supply size----------- 3/4-inch N.P.T. (minimum)

Btu/hr input (per dryer) - 200,000

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column (W.C.)
pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 11.0 inches water column (W.C.). There is no regulator or
regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P.
tank) or an external regulator must be added to each dryer.

Type of Gas

LR

Conversion

Kit

Part Number

MODEL

NUMBER

BTU

Per Hour

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty-

D.M.S.*

Part

Number

ADG-78

200,000

4

#29

140820

4

#47

140805

881655

* D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas....................

#29 = .1360"

Liquid

Propane Gas ... #47 = .0785"

27