Aa. condensation on main door glass, Bb. scraping noise at basket (tumbler) area, Cc. excessive noise and/or vibration – ADC AD-78 User Manual

Page 61: Z. main burners are burning with a yellow flame

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

2.

Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local

conditions.

Z. Main burners are burning with a yellow flame

(for Gas Models ONLY)...

1. Poor air/gas m ixture (too m uch gas or not enough air) at the burner...

a. Not enough m ake-up air.

b. Restriction in the exhaust.

c. G as pressure is too high.

d. Im pellor (fan/blower) is rotating in the wrong direction only

(for 30 Models ONLY).

e. Burner orifice size (D.M .S. [drill m aterial size]) too large for application (i.e., high elevation).

AA. Condensation on main door glass...

1. Too long, undersized, or im properly installed duct work.

2. Back draft dam per is sticking in the partially closed position.

BB. Scraping noise at basket (tumbler) area...

1. Check for obstruction caught in basket (tum bler)/wrapper area.

2. Basket (tum bler) is out of proper alignm ent...

a. Check both the vertical alignm ent and lateral alignm ent.

b. Check for gap between the front panel and basket (tum bler)...bearing set screws m ay have com e

loose, and basket (tum bler) walked forward or backward.

3. Loose basket (tum bler) tie rod.

4. Failed basket (tum bler) support.

CC. Excessive noise and/or vibration...

1. Dryer is not leveled properly.

2. Im pellor (fan/blower) out of balance ...

a. Excessive lint build up on im pellor (fan/blower).

b. Failed im pellor (fan/blower).

3. Loose basket (tum bler) tie rod.

4. Failed basket (tum bler) support.