1. Fault in lint cham ber sensor bracket basket (tum bler) hi-lim it.

U. Heating unit is not operating (no heat)...no voltage at heating unit (i.e.,

Gas Model

- Hot

Surface Ignition [HSI] module,

Electric Model

- electric oven contactor, or

Steam Model

-

steam damper system pneumatic solenoid) when dryer is first started and both the heat
indicator dot and the "HEAT" output L.E.D. (light emitting diode)»

not on...

1. Failed m icroprocessor controller (com puter).

V. Heating unit |s not operating (no heat)...no voltage at heating unit (i.e..

Gas Model

-

Hot

Surface Ignition [HSI] module.

Electric Model

-

electric oven contactor, or

Steam Model -

steam damper system 3-way micro valve)...

GAS MODELS...

1. Fault in hot surface ignition system ...

a. H ot surface ignitor glows but no ignition and H SI m odule "L,O CK S-O UT" ("red" L.E.D. indicator

flashes)...

1) Flam e probe assem bly is out of adjustm ent or has failed.

2) Severe air turbulence.

3) Failed H SI m odule.

4) Failed gas valve.

b. H ot surface ignitor glows, but burner goes off right away ...

1) Flam e probe assem bly is out of adjustm ent or has failed.

2) Sail switch is fluttering ...

a) Lint screen is dirty.

b) Restriction in exhaust duct work.

c. H ot surface ignitor does not glow and H SI m odule "LO CK S-O UT" ("red" L.E.D. indicator flashes)...

1) Fault in hot surface ignitor wiring...break or loose connection.

2) Failed hot surface ignitor.

3) Failed H SI m odule.

STEAM M ODELS...

52

Advertising