7 reset status – ADLINK ND-6054 User Manual
Page 76
68
• Command Set
3.7 Reset
Status
( 6050, 6052, 6053, 6054,
6056, 6058, 6060, 6063 )
@Description
Checks the reset status of module at specified address to see whether it has
been reset since the last reset status command was issued to the module.
@Syntax
$(Addr)5<CR>
$
Command leading code.
(Addr) Address
ID.
5
Reset Status Command.
@Response
!(Addr)(Status)<CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr) Address
ID.
(Status)
0 : It has not been reset since the last reset status
command was issued.
1 : It has been reset since the last reset status
command was issued.
@Example
User command:
$305<CR>
Response:
!300<CR>
Status is 0 means this digital I/O module has not been reset,
since the last reset status command was issued.