12 synchronized sampling – ADLINK ND-6054 User Manual
Page 85
Advertising
![background image](/manuals/733493/85/background.png)
Command Set
• 77
3.12 Synchronized Sampling
( 6050, 6052, 6053, 6054,6058, 6060, )
@Description
Synchronized all modules to sample input values and stored the values in
the module’s register at the same time and use “Read Synchronized Data”
command to read the data and process it one by one.
For digital I/O module, this command is only available to modules involving
the digital input function, such as NuDAM-6050, NuDAM-6052,
NuDAM-6053, NuDAM-6054, NuDAM-6058 and NuDAM-6060.
@Syntax
#**<CR>
#
Command leading code.
**
Synchronized sampling command
@Response
Note : Synchronized sampling command has NO response.
@Example
User command:
#**<CR>
Synchronized sampling command has no response.
Advertising