13 read synchronized data – ADLINK ND-6054 User Manual

Page 86

Advertising
background image

78

Command Set

3.13 Read Synchronized Data

( 6050, 6052, 6053,6054, 6058, 6060 )

@Description

After a synchronized sampling command #** was issued, you can read the
input value that was stored in the addressed module’s register and use same
method to process other module‘s data one by one.

@Syntax

$(Addr)4<CR>

$

Command leading code.

(Addr) Address

ID.

4

Read synchronized data.

@Response

ND-6050 module response :

!(Status)(DataOut)(DataIn)00<CR>

ND-6052 module response :

!(Status)(DataIn)0000<CR>

ND-6053 module response :

!(Status)(DataInH)(DataInL)00<CR>

ND-6054 module response :

!(Status)(DataInH)(DataInL)00<CR>

ND-6058 module response :

!(Status)(IOFlag)(DIn)(DataInA)(DataInB)(DataInC)<CR>

ND-6060 module response :

!(Status)(DataOut)(DataIn)00<CR>

or

?(Addr)<CR>

!

Command is valid.

?

Command is invalid.

Advertising