Remote System Upgrade Circuitry

Figure 2-4: Remote System Upgrade Circuitry

Status Register (SR)

Previous

State

Register 2

Bit[31..0]

State

Register 1

Bit[31..0]

Current

State

Logic

Bit[33..0]

Internal Oscillator

Control Register

Bit [38..0]

Logic

Input Register

Bit [38..0]

update

Logic

Bit [40..39]

dout

din

Bit [38..0]

dout

din

capture

Shift Register

clkout capture

update

Logic

clkin

RU_DIN

RU_SHIFTnLD

RU_CAPTnUPDT

RU_CLK

RU_nRSTIMER

Logic Array

RU

Reconfiguration

State

Machine

User

Watchdog

Timer

RU

Master

State

Machine

timeout

RU_nCONFIG

RU_DOUT

Previous

The remote system upgrade circuitry does the following functions:
• Tracks the current state of configuration

• Monitors all reconfiguration sources

• Provides access to set up the application configuration image

• Returns the device to fallback configuration if an error occurs

• Provides access to the information on the failed application configuration image

Remote System Upgrade Circuitry Signals

Table 2-6: Remote System Upgrade Circuitry Signals for MAX 10 Devices

Core Signal Name

Logical

Signal

Name

Input/

Output

Description

RU_DIN

regin

Input

Use this signal to write data to the shift register on the rising

edge of

RU_CLK

. To load data to the shift register, assert

RU_

SHIFTnLD

.

2-10

Remote System Upgrade Circuitry

UG-M10CONFIG

2015.05.04

Altera Corporation

MAX 10 FPGA Configuration Schemes and Features

Send Feedback

Advertising