In user mode, MAX 10 devices support the

CHANGE_EDREG

JTAG instruction, which allows you to write to

the 32-bit storage register. You can use .jam to automate the testing and verification process. You can

only execute this instruction when the device is in user mode. This instruction enables you to dynamically

verify the CRC functionality in-system without having to reconfigure the device. You can then switch to

use the CRC circuit to check for real errors induced by an SEU.
After the test completes, to clear the CRC error and restore the original CRC value, power cycle the device

or follow these steps:
1. After the configuration completes, use

CHANGE_EDREG

JTAG instruction to shift out the correct

precomputed CRC value and load the wrong CRC value to the CRC storage register. When an error is

detected, the

CRC_ERROR

pin will be asserted.

2. Use

CHANGE_EDREG

JTAG instruction to shift in the correct precomputed CRC value. The

CRC_ERROR

pin is de-asserted to show that the error detection CRC circuitry is working.

Related Information

SEU Mitigation and Configuration Error Detection

on page 2-18

Enabling Error Detection

The CRC error detection feature in the Quartus II software generates the

CRC_ERROR

output to the

optional dual-purpose

CRC_ERROR

pin.

To enable the error detection feature using CRC, follow these steps:
1. Open the Quartus II software and load a project using MAX 10 device family.

2. On the Assignments menu, click Settings. The Settings dialog box appears.

3. In the Category list, select Device.

4. Click Device and Pin Options.

5. In the Device and Pin Options dialog box, click the Error Detection CRC tab.

6. Turn on Enable error detection CRC.

7. In the Divide error check frequency by field, enter a valid divisor.

The divisor value divides down the frequency of the configuration oscillator output clock. This output

clock is used as the clock source for the error detection process.

8. Click OK.

Related Information

SEU Mitigation and Configuration Error Detection

on page 2-18

Accessing Error Detection Block Through User Interface

The error detection circuit stores the computed 32-bit CRC signature in a 32-bit register. The user logic

from the core reads out this signature. The

fiftyfivenm_crcblock

primitive is a WYSIWYG component

used to establish the interface from the user logic to the error detection circuit. The

fiftyfivenm_crcblock

primitive atom contains the input and output ports that must be included in the

atom. To access the logic array,you must insert the

fiftyfivenm_crcblock

WYSIWYG atom into your

design. The recommended clock frequency of .clk port is to follow the clock frequency of EDCRC block.

UG-M10CONFIG

2015.05.04

Enabling Error Detection

3-9

MAX 10 FPGA Configuration Design Guidelines

Altera Corporation

Send Feedback

Advertising