Relay Outstation

QLRi2 Mk4

Relay Outstation QLRi2 Mk4

19.

The Relay Outstation provides two voltage free changeover
relay contacts controlled by the Master Station.
Relay A is controlled by the Standby button.
Relay B is controlled by the Go command.
The relay contacts are rated at 2 amps 30 volts AC or DC.

An external

Confirm

button may be connected if required.

normally open momentary acting

These 5 modes can be programmed via the Master Station
Configuration Editor
(page 34) or by using the Setup
button
on the Relay Outstation.
To prevent accidental mode changes, the Setup button is
interlocked with an Enable button
To change the mode, press and hold the Enable button
After a 500mS delay, the Setup button will light indicating
that it is enabled. Pressing the Setup button will step
through the modes.
Any configuration changes made this way are sent to the
Master Station and saved in the Master Station’s memory
for recall next time the system is powered up.

The Relay Outstations have 5 modes of operation.

Relay A

Relay B

Controlled by
Standby button

Controlled by
Go button

Momentary
Latched
Momentary
Latched
Cue Light Mode

Momentary
Latched
Latched
Momentary
Cue Light Mode

1

2

2

1

2

Photos were reduced to the required size in Photoshop.
File name contains the width in mm.
Most photos were done at 300dpi.

CDR file was printed using File, Publish to PDF menu option.
Down sampling was turned off.
JPG compression was set to 20.

Resulting PDF was then opened in Acrobat 6
menu: Advanced, PDF Optimizer.
Images tab: Turn off all down sampling.
Cleanup tab: Check “Remove document structure” and
“hidden layer content and flatten layers”

Relay connections

Pin 1

Pin 8

Pin

Relay A

Relay B

pins 4 & 5 not used

Common
N.C.
N.O.

Common
N.C.
N.O.

Advertising