Master station configuration editor – Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual

Page 43

Advertising
background image

Designed and created by:-

Built By

Relay A

Relay B

Momentary
Latched
Momentary
Latched
Cue Light Mode

Momentary
Latched
Latched
Momentary
Cue Light Mode

The 5 Relay Modes

Controlled by
Standby button

Controlled by
Go button

43.

Each Relay must be assigned to one of 5 modes.
Select a Relay Mode from these 5 buttons
When any of these buttons are pressed, two buttons will
illuminate yellow lamps to indicate the selected option.

The green buttons indicate the status of the selected
mode for each of the 16 channels. When a green button is
illuminated, that channel is assigned to the selected mode.

Pressing a green button assigns that Relay to the selected
mode. Once assigned to a particular mode, that channel
cannot be deselected by pressing its green button a second
time. To deselect a Relay from a particular mode, just
assign it to the required mode and that action will deselect it
from all other modes.

Relay options (grey buttons)

Relay Mode

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Power

5 modes for each Relay

Options for Relay’s Cue Light Mode

More Relay Options

6

Assign Relay #12 to A:momentary B:Latch mode.

Start the Configuration Editor
Select Page 2
Select A:momentary B:Latch mode
Press green button for channel 12
Save to the ShowTime file
Save to User file 1-4 (optional)
Exit the Configuration Editor

Example:

Change mode for Relay #12

7

Master Station Configuration Editor

Relay Outstation options

1

2

3

1

4

5

1

8

Momentary: Relay operates only while the button is pressed.
Latching:

Press the button to set (turn on) the Relay.
Press it again to reset (turn off) the Relay.

1
2
3
4
5

(continued)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Power

Theatre Cue Light

Master QLM16i2 Mk4

www.interspaceind.com

Innovation by:-

Built By:-

4

Relay

Options

Edit

Channel

Sensor

Options

Safe when

open

Unsafe
flashes

No

EOL

All lamps

enabled

S/by flash
on Master

S/by flash
on Outstn

S/by

latches

Go

times out

Go

flashes

Go

latches

Go & S/by

interlocked

Call lamp

enabled

Call lamp

flashes

All lamps

enabled

Edit all

16 ch.

Open

Save

Relay & Sensor.

Page 2

Select

page

Exit

A: Latch
B: Latch

A: Mom
B: Latch

A: Latch
B: Mom

Cue Light

Mode

A: Mom
B: Mom

5

Installer
defaults

User 1

User 2

User 3

User 4

Show

Time

Factory

default red

Factory

default yel

6

7

8