A wiring example, Outstation cables – Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual

Page 30

Advertising
background image

Designed and created by:-

Built By

This example shows how a theatre might be permanently
wired using a mix of daisy chain and star wiring.
Backbone cable segments in green are wired with a thicker
cable as these have a larger number of outlets attached to
them.
The Master Station unit could be located at XLR point #8
during rehearsals. The cable between the patch panel and
points #8 would have to carry 100% of the Outstation load,
hence the thicker cable.
Small venues, or those using 8 or less Outstations, could be
cabled entirely in 24 AWG.

Typical cables would be:-

24 AWG - Belden 9841
20 AWG - Belden 9463

Theatre wiring example.

1: Fly Gallery
2: Stage traps
3: Stage
4: Orchestra Pit

Patch
Panel

Stage

Stalls

Pit

Balcony

3

3

3

2

2

2

3

2

2

2

3

1

1

1

4

4

4

6

5

6

6

7

7

5

5

7

1

7

8

8

5: Balcony
6: Lighting & spots
7: Doors
8: Sound & Rehearsal desk.

24 AWG cable
20 AWG cable

Permanently wired Cue Light XLRs

1

1

1

3

3

3

A wiring example

30.

Outstation Cables

(Continued)