Configuration editor, Alternate button overlays – Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual

Page 35

Advertising
background image

Designed and created by:-

Built By

Page 1: Cue Light Outstation and Master Station configuration

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Power

Theatre Cue Light

Master QLM16i2 Mk4

www.interspaceind.com

Innovation by:-

Built By:-

Page 2:

configuration

Relay & Sensor

Relay

Options

Sensor

Options

Select

page

Save

Open

S/by flash
on Master

S/by flash
on Outstn

S/by

latches

Go

times out

Go

flashes

Go

latches

Go & S/by

interlocked

Call lamp

enabled

Call lamp

flashes

All lamps

enabled

A: Latch
B: Latch

A: Mom
B: Latch

A: Latch
B: Mom

Cue Light

Mode

A: Mom
B: Mom

Page 2

Relay & Sensor.

5 modes for each Relay

Options for Relay’s Cue Light Mode

More Relay Options

Select an Option to edit

from the grey & yellow boxes

Start the Configuration Editor.

Editor starts with the ShowTime file opened and option #1 selected.

Open one of 8 files

Save to the Show Time file if you want those settings to run the Cue Light system.

Save to User files 1-4 (optional)

Select options page 1 or 2

Exit the Editor

Edit options on a channel by channel basis

Green button lit = option active

35.

1

2

4

3

5

6

7

3

Edit

Channel

Read only files

Read/write files

defaults

Read page

rst or you may waste a lot

of time. These pages will walk you through the
basic steps of using the Editor.

s 36 & 37 fi

Configuration Editor

Alternate button overlays

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Power

Theatre Cue Light

Master QLM16i2 Mk4

www.interspaceind.com

Innovation by:-

Built By:-

Cue Light

Options

Edit

Channel

Master

Options

Edit all

16 ch.

Page 1

Cue Light & Master.

Select

page

Save

Exit

To start the Editor

press 3 buttons

for 4 seconds

Master’s

Address

Group btns

linked

3

6

7

4

5

2

Open

1

Installer
defaults

User 1

User 2

User 3

User 4

Show

Time

Factory

default red

Factory

default yel

Exit

6

7

2

4

5

Edit all

16 ch.

Safe when

open

Unsafe
flashes

No

EOL

All lamps

enabled

Installer
defaults

User 1

User 2

User 3

User 4

Show

Time

Factory

default red

Factory

default yel

S/by flash
on Master

S/by flash
on Outstn

Standby

Latches

Dim on

ACK

Go

flickers

Go

times out

Go

flashes

Go

latches

Go & S/by

interlocked

Call lamp

enabled

Call lamp

flashes

ACK back-

light on

Beepers

enabled

Beep

on Go

Dimmers

to 100%

Yellow

Standby

4

4

Advertising