45.

The Sensor Outstation has 4 options ,3 of which are
programmable from the Outstation’s front panel.
When an option is changed from the Outstation, the change
is sent to the Master Station and saved in the Master
Station’s ShowTime file for recall next time the system is
turned on.
To save ShowTime file changes to one of the 4 User files,
follow the steps in the example below.

Unsafe lamp Flashes
No End-of-Line resistors
All lamps enabled

Safe when open

when open
Flashes
No resistors
Enabled

Steady
2 EOL resistors
Off

Safe when closed

Sensor Outstation options

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

www.LeonAudio.com.au

Cue Light

Master

QLM16 Mk4

Power

1

Factory
Default

User Selectable
Option

Options

Sensor options
( this feature coming soon- not yet available)

Master Station Configuration Editor

Start the Configuration Editor.
The Editor opens with the ShowTime file already loaded.
Save the ShowTime file to User file 1-4.
Exit the Configuration Editor.

Example:

Saving changes made to the ShowTime file

5

Select an option to edit by using the yellow buttons
The button will light to indicate the selection.

Toggle all 16 channels at once by using the Edit all 16 ch
button

The All lamps enabled option can only be edited by using
the Master Station Configuration Editor. This option blanks
all lamps on the Sensor Outstation which is useful when the
Sensor Outstation needs to hide from public view.
When the lamps are disabled, pressing the Grey Enable
button on the Outstation will momentarily light the
Outstation’s lamps so that its operation can be monitored or
its mode changed.

Edit that option on a channel by channel basis using the
Green buttons (Green button lit = option active)

1

Start the Configuration Editor
Select Page 2
Select No EOL option
Press the green button for channel 4 to deselect the
No EOL option.
(Green button lit = no EOL resistors)
(Green button not lit = 2 EOL resistors)
Save to the ShowTime file
Save to User file 1-4 (optional)
Exit the Configuration Editor

Example:

(set Sensor #4 to use 2 End-of-Line resistors)

4

5

6

2

3

(continued)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Power

Theatre Cue Light

Master QLM16i2 Mk4

www.interspaceind.com

Innovation by:-

Built By:-

Relay

Options

Sensor

Options

Edit

Channel

Open

Edit all

16 ch.

Exit

Select

page

Relay & Sensor.

Page 2

Save

S/by flash
on Master

S/by flash
on Outstn

S/by

latches

Go

times out

Go

flashes

Go

latches

Go & S/by

interlocked

Call lamp

enabled

Call lamp

flashes

All lamps

enabled

A: Latch
B: Latch

A: Mom
B: Latch

A: Latch
B: Mom

Cue Light

Mode

A: Mom
B: Mom

Safe when

open

Unsafe
flashes

All lamps

enabled

Installer
defaults

User 1

User 2

User 3

User 4

Show

Time

Factory

default red

Factory

default yel

No

EOL

1

4

6

2

3

Advertising