Installation, 1 starting nuwin – Xtramus NuWIN V1.1 User Manual

Page 38

Advertising
background image



33

E-mail: [email protected]

Website: www.

X

tramus.com

XTRAMUS TECHNOLOGIES

®

3. Installation

Unlike NuStreams-2000i, NuStreams-600 does not include PC. Before installing

NuWIN to the PC controlling NuStreams-600, connect the XM-2S23 Internal Switch

Module of the NuStreams-600 to the LAN port of the PC which users will be working on

through a UTP cable.

3.1 Starting NuWIN

1. Insert the CD-ROM containing NuWIN driver into the PC’s CD-ROM drive (If

AutoPlay is envoked, the installation starts automatically and skip step 2.)

2. Choose Start/Run and click Browse button, then the Browse window appears. In

the Browse window, select CD-ROM drive and autorun.exe file, then click Open.

3. Follow the on-screen prompts to complete the installation from top to bottom. The

files are copied to the directory specified by users (default C:\program

files\NuStreams\NuWIN)

3.1 Please note that in order to update NuWIN, the older version should be

uninstalled first beofre installing the newer one, otherwise NuWIN could not be

installed properly. Reboot the system after installing the new NuWIN.

3.2 At the start of NuWIN, if “cannot find the module” message appears, there must

be an old version of library not completely removed. Manually delete

C:\WINNT\System32\dclus*.bpl and reinstall the new version of NuWIN.

4. To update Firmware online, please go to Report/Card Version/Updates Firmware

through the popup menu of Chassis window or Tools/Option of the Main Menu Bar.

5. Check the Log Wndow to see if all the cards respond with an ACK signal in about

six minutes. If any of the cards fail to do so, check if its SYS LED indicator on the

front panel on the chassis is on.

6. Go to Report/Card Version of popup menu of Chassis window to verify the current

edition of Firmware/FPGA.