Maintenance, 1 firmware update – Adept T2 Pendant User Manual

Page 41

Advertising
background image

Adept T2 Pendant User’s Guide, Rev D

41

Maintenance

5

5.1

Firmware Update

The process to update the system firmware includes installing a USB memory stick that
contains the new firmware files from Adept. The USB memory stick must meet the
following requirements:

• Type: USB 2.0 memory stick

• Memory size: 128 MB or greater

Procedure:

1. Verify that you have the USB memory stick with the new firmware files.

2. Disconnect the T2 pendant from the controller.

3. Insert the USB memory stick into the T2 pendant.

See the procedure on the following page for the details on installing the USB
memory stick.

4. With the USB memory stick installed, connect the T2 pendant to the controller.

5. From the main screen on the T2 pendant, press the SYS MENU button.

6. On the System Menu screen, press Firmware Update, and follow the instructions

to do the update.

7. After the update has completed, remove the USB memory stick.

See the procedure on the following page for the details on removing the USB
memory stick.