Troubleshooting

Table 5-1. Troubleshooting Information

Problem

Solution

The touchscreen becomes
unresponsive.

1. Go to the System Menu and run the
Touchscreen Calibration process.

2. If step 1 does not solve the problem, or you
cannot access the System Menu, then use this
process. Press these four buttons at the same
time: Robot Power On, Robot Power Off, J1+, and
J1-. This puts the T2 pendant back into the
Touchscreen Calibration screen. Perform the
calibration carefully, to make sure the screen is
responsive to the stylus.

The touchscreen becomes
unreadable due to the brightness
being set too low.

Press these four buttons at the same time: Robot
Power On, Robot Power Off, J2+, and J2-. This
restores the T2 pendant the default brightness
setting.