For digital channel, there are five alarm types. See Figure 4-100 through Figure 4-104.
 Local alarm: The alarm signal system detects from the alarm input port.
 Network alarm: It is the alarm signal from the network.
 HDCVI: System can get the camera temperature, smoke, external alarm and set

corresponding alarm activation operation.

 IPC external alarm: It is the on-off alarm signal from the front-end device and can

activate the local HDVR.

 IPC offline alarm: Once you select this item, system can generate an alarm when the

front-end IPC disconnects with the local HDVR. The alarm can activate record, PTZ,

snap and etc. The alarm can last until the IPC and the HDVR connection resumes.

Important

If it is your first time to boot up the device, the disconnection status of

the front-end network camera will not be regarded as offline. After one

successfully connection, all the disconnection events will be regarded

as IPC offline event.

When IPC offline alarm occurs, the record and snapshot function of

digital channel is null.

 Alarm in: Here is for you to select channel number.
 Type: normal open or normal close.
 PTZ activation: Here you can set PTZ movement when an alarm occurs. Such as go

to preset, tour& pattern when there is an alarm. Click “select” button, you can see an
interface is shown as in Figure 4-105.

 Period: Click set button, you can see an interface is shown as in Figure 4-106. There

are two ways for you to set periods. There are max 6 periods in one day. There are

four record types: regular, motion detection (MD), Alarm, MD & alarm.

 In

Figure 4-106, Select icon

of several dates, all checked items can be

edited together. Now the icon is shown as

.

Click

to delete a record

type from one period.

 In

Figure 4-106. Click button

after one date or a holiday, you can see an

interface shown as in Figure 4-107. There are four record types: regular, motion

detection (MD), Alarm, MD & alarm.

 Anti-dither: Here you can set anti-dither time. Here you can set anti-dither time. The

value ranges from 5 to 600s. The anti-dither time refers to the alarm signal lasts time.

It can be seem as the alarm signal activation stays such as the buzzer, tour, PTZ

activation, snapshot, channel record. The stay time here does not include the latch

time. During the alarm process, the alarm signal can begin an anti-dither time if

system detects the local alarm again. The screen prompt, alarm upload, email and etc

will not be activated. For example, if you set the anti-dither time as 10 second, you

can see the each activation may last 10s if the local alarm is activated. During the

process, if system detects another local alarm signal at the fifth second, the b uzzer,

tour, PTZ activation, snapshot, record channel will begin another 10s while the