51

Surge voltage

Between touches with same

polarity

1500V (10×160us)

Length of open

time

3ms max

Length of close

time

3ms max

Longevity

Mechanical

50×106 times (3Hz)

Electrical

200×103 times (0.5Hz)

Temperature

-40℃ ~+70℃

3.7 RS485

When the DVR receives a camera control command, it transmits that command up the coaxial

cable to the PTZ device. RS485 is a single-direction protocol; the PTZ

device can’t return any

data to the unit. To enable the operation, connect the PTZ device to the RS485 (A,B) input on

the DVR.

Since RS485 is disabled by default for each camera, you must enable the PTZ settings first.

This series DVRs support multiple protocols such as Pelco-D, Pelco-P.

To connect PTZ devices to the DVR:

1. Connect RS485 A,B on the DVR rear panel.

2. Connect the other end of the cable to the proper pins in the connector on the camera.

3. Please follow the instructions to configure a camera to enable each PTZ device on the

DVR.

Figure 3-3

Figure 3-4

Figure 3-5

485 Port

485 Port

485 Port