AMETEK SLH Series RevC User Manual

Page 19

Advertising
background image

Sorensen SLH-Series DC High Power Electronic Load

Introduction

CR Mode:

In Constant Resistance mode, the load will sink a current linearly proportional to the load
input voltage in accordance with the programmed resistance setting (see Figure 1-8).

Figure 1-8 Constant Resistance (CR) Mode

CV Mode:

In Constant Voltage mode, the load will attempt to sink enough current until the load
input voltage is equal to the programmed voltage setting (see Figure 1-9).

Figure 1-9 Constant Voltage (CV) Mode

Dynamic Waveform Definition

There are six parameters to generate dynamic wave form or pulse wave form: High/Low
load levels, Rise/Fall slew rates, and T

HIGH

/T

LOW

durations. The SLH-series Electronic

Load will sink current from the power source proportional to the dynamic waveform. The
dynamic waveform definition is shown in Figure 1-10. The period of dynamic wave form
is, dynamic frequency = 1 /(T

HIGH

+ T

LOW

), the Duty cycle = T

HIGH

/ (T

HIGH

+ T

LOW

)

The formula to define the period of dynamic waveform (T

HIGH

+ T

LOW)

is:

M540074-01

Rev C

1-5