5 sequence function, Sequence function – AMETEK SLH Series RevC User Manual

Page 46

Advertising
background image

Operation

Sorensen SLH-Series DC High Power Electronic Load

3.5

SEQUENCE FUNCTION

There are two modes in the SEQUENCE function: EDIT MODE and TEST MODE, The AUTO SEQ
function can be initiated by pressing State 3 + State 4 keys simultaneously. To enter EDIT MODE,
press STORE; to enter the TEST MODE, press START key. Please refer to the flow chart in Figure
3-7. A brief description of each mode follows the flow chart.

Press

S3+S4 Buttons
Simultaneously

EDIT Seq or

RUN Seq

Press

BANK Up/Down

Keys to select

sequence number

Bank LED

Display

Start

EDIT

RUN

Press

START Button

Testing

Memory Bank

and State

under test

End?

Step = Step + 1

Exit?

Press

EXIT Button

Pass/Fail

Display GO

Display NG

YES

Test

sequence

number nx

NO

YES

NO

PASS

FAIL

Press Exit Key

GO / NG

1

1

Test sequence

number nx

Press

STORE Button

Step Number

Select Memory

Location: Press
Bank Up/Down,

State 1-5

Press STORE

Button

t1 test time,

when STORE

is released

Press BANK Up/

Down to select t1

time in 0.1sec

Press STORE

Button

t2 delay time,

when STORE

is released

Press BANK Up/

Down to select t2

time in 0.1sec

Press STORE

Button

Is Step=16 (F)

YES

End?

Step=Step+1

NO

NO

YES

Bank Number

Press

EXIT Button

Bank LED

Display

1

"t1" when

STORE button

is held

"t2" when

STORE button

is held

Figure 3-7 Auto Sequence Function Set-Up and Operation Flowchart

3-16

M540074-01

Rev C

Advertising