The following specifications apply 25 °c ± 5°c – AMETEK SLH Series RevC User Manual

Page 93

Advertising
background image

Sorensen SLH-Series DC High Power Electronic Load

Appendix B

The following specifications apply 25

°C ± 5°C:

Model

SLH-60-240-3600

INPUT RATINGS

VOLTAGE

60 V

CURRENT

240 A

POWER

3600 W

CC MODE

Range

0-24 / 0-240 A

Resolution

6.4/64 mA

Accuracy ±0.2% OF (SETTING + RANGE)

CR MODE (1)

Range 1 (I>0.05% of rating)

0.25 - 937.5Ω

Range 2 (I>0.5% of rating)

0.0133 - 0.25 Ω

CV MODE

Range

2 - 60V

Resolution

0.015V

Accuracy ±0.1% OF (SETTING + RANGE)

CP Mode

Range

0-3600W

Resolution

0.96W

Accuracy ±0.5% OF (SETTING + RANGE)

SHORT MODE

Max. Resistance

2mΩ

Current

240 A

DYNAMIC MODE

Thigh/Tlow

50uS to 9.999 Sec

Slew Rate Low

2mA - 500mA/uS

Slew Rate High

20mA - 5A/uS

Accuracy

±10% OF SETTING + 10

μs

4 1/2 DVM

Range

0 - 20.00/60.00V

Resolution

0.001/0.01V

Accuracy ±0.05% OF (READING + RANGE)

4 1/2 DAM

Range

0 - 24/240 A

Resolution

1 / 10 mA

Accuracy ±0.5% OF (READING + RANGE)

Imonitor

24 A/V

PROTECTION

OPP

~1890 W

OCP

~252 A

OVP

~ 63 V

OTP

~ 85℃

Load ON Volt.

Range

0.1 - 25V

Resolution

0.1V

Accuracy

1% of Setting + 0.25V

Load OFF Volt.

Range

0 - 25V

Resolution

0.002V

Accuracy

0.05% of Setting + 0.0125V

ENVIRONMENTAL

Operating Temp.

0-40 °C

SLH-60-240-3600 Master/Slave

0

15

30

45

60

0

60

120

180

240

Current (Amps)

Vo

lt

a

g

e

(

V

)

Table B-2 SLH-Series Specifications

Figure 8 Power Curve

M540074-01

Rev C

B-9

Advertising