AMETEK SLH Series RevC User Manual

Page 71

Advertising
background image

Sorensen SLH-Series DC High Power Electronic Load

Remote Programming

For Example :

LDOF 2.0 ; Set the Load Off voltage to 2.0V. The load will start to sink current when power source
output voltage is lower than 2.0V.

LEVEL HIGH/LOW

Purpose:
Select Low or High level in static mode, of DC electronic loads.

Command Syntax:
LEVE {SP}{HIGH|LOW}{NL}

Description:
LEVE LOW is Set LOW current level in CC mode, LOW resistance level in CR mode, or LOW
voltage level in CV mode at the active load channel.
LEVE 1 is Set HIGH current level in CC mode, HIGH resistance level in CR mode, or HIGH voltage
level in CV mode at the active load channel.

PRESET ON/OFF

Purpose:
Set the upper or lower digit multi-function meter to display the programmed load level.

Command Syntax:
PRES{SP}{0|1|OFF|ON}{NL}

Description:
PRES ON is set the load to preset on status.

MODE

Purpose:
Select the operating mode of Electronic load module.

Command Syntax:
MODE{SP}{0|1|2|3|CC|CR|CV|CP}{NL}

Description:
MODE CC ; set the presently operating mode to Constant Current mode for all of the load module in
the SLH mainframe.
MODE CV ; set the presently operating mode to Constant Voltage mode.
MODE 1 ; set the presently operating mode to Constant Resistance mode.
MODE CP ; set the presently operation mode to Constant Power mode.

CLEAR status register

Purpose:
CLEar the PROT and ERR status byte registers.

Command Syntax:
All Modules:

CLER{NL}

Description:
CLER ; clear the PROT and ERR status byte register, the PROT and ERR status byte register will
indicate “0" after executing the CLER command.

M540074-01

Rev C

5-9

Advertising