Installation, Ab c d e – Avalon Firestyles AGP Pellet User Manual

Page 11

Advertising
background image

Installation

(For Qualified Installers Only)

11

© Travis Industries

4141230

100-01341

Hopper Extension Set-up


This pellet insert has a variable-height hopper. On large fireplaces (24” or greater height) the hopper may
be extended to the upper position, increasing hopper capacity. On smaller fireplaces (under 24” fireplace
height) the hopper top may be placed in a lower position.

Use the chart below to determine the hopper extension position.

Hopper Extension Position

Hopper Height

A Lowest

Position

21”

B Mid-Low

21.75”

C Middle

Position

22.5”

D Mid-High

23.25”

E

Highest

24”

The hopper extends 14.25” into the fireplace. For determining the maximum hopper extension,
measure the fireplace 14.25” into the fireplace.


The hopper top is shipped attached to the hopper assembly with shipping screws. Follow the instructions
below to attach the hopper top to the hopper assembly using the screws included in the owner’s pack.
Determine the correct hopper extension based on the table below.


A

B

C

D

E

Shipping Screw (both sides)