Installation, For qualified installers only), Heating specifications – Avalon Firestyles AGP Pellet User Manual

Page 7: Dimensions, Electrical specifications, Fuel, Emissions

Advertising
background image

Installation

(For Qualified Installers Only)

7

© Travis Industries

4141230

100-01341

Heating Specifications

Approximate Maximum Heating Capacity (in square feet)* ............................................ 800 to 2,000 Sq. Feet
BTUs .............................................................................................................................. 11,480 to 41,000 **
Burn Rate (Pounds per Hour)*** .................................................................................... 1.4 to 5
Maximum Burn Time on Low Burn*** ............................................................................. 28 to 50 Hours
Hopper Capacity ............................................................................................................ 40 to 70 Pounds
Turn-Down Ratio ............................................................................................................ 72%

*

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is
also affected by the fuel size, quality, and moisture level.

**

Based on 8,200 BTUs per pound.

*** Small pellet size will decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on

fuel quality may occur.

Dimensions

Electrical Specifications

Electrical Rating ...................................................................................................... 115 Volts, 3 Amps, 60 Hz
Watts during Start-Up Sequence ............................................................................ 350 (approximately)
Watts during Operation ........................................................................................... 250 (approximately)

Fuel

This heater is designed and approved for pelletized wood fuel only (all grades).

Emissions

0.66 Grams per Hour (EPA Phase II Approved)

3" (77mm) Dia. Exhaust

1.75" (45mm) Dia. Intake

Fireplace Opening

33.25" (845mm) Min. Fireplace Width

14.25" (362mm)

Min. Fireplace Depth

10" (254mm)

Extension Onto Hearth

Centerline

24.75" (629mm)

42" (1067mm)

Control Panel

24" (610mm) Maximum
Hopper Setting (70 lb.)

21" (534mm) MInimum
Hopper Setting (40 lb.)

26"

(661mm)

30.5"

(775mm)

Front of Firebox

(for measuring hearth requirement)

11.5"
293mm

8.375" 213mm

8.375"
213mm

21.75" (553mm)