Maintenance

41

© Travis Industries

4141230

100-01341

Access and Clean Components

The insert may be removed to inspect and access the components. Follow the directions below to
remove the insert from the fireplace.

DISCONNECT THE POWER CORD (OR DISABLE THE BREAKER) AND MAKE SURE THE
HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) PRIOR TO CONDUCTING
SERVICE.

1. Remove the surround panel (and control panel) and place aside.
2. Use the latch to disconnect the flue assembly from the insert.
3. Place protection on top of the hearth to protect it against scratches.
4. Slide the insert forward 4” to 12” to gain access to the components (if necessary).
5. Use a vacuum/compressed air to clean the internal components (cooling fan, auger motor, etc.).

Clean the Exhaust Blower

MAKE SURE THE HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) BEFORE
CONDUCTING SERVICE.

THE ASHPAN MUST BE IN PLACE WHILE THE HEATER IS IN USE.

1. Remove the insert from the fireplace (see above).
2. Loosen the 8 screws holding the intake duct cover in place (11/32” nutdriver). Remove the intake

duct cover by sliding it up and off the studs (the gasket will remain in place).