Maintenance

© Travis Industries

4141230

100-01341

3. Loosen the 8 screws holding the exhaust duct cover in place (11/32” nutdriver). Remove the exhaust

duct cover by sliding it up and off the studs (the gasket will remain in place).

4. Clean the exhaust blower with a bottle brush or vacuum.

NOTE: Take care to prevent damaging the combustion blower impellers.