Maintenance – Avalon Firestyles AGP Pellet User Manual
Page 42
Advertising
42
Maintenance
© Travis Industries
4141230
100-01341
3. Loosen the 8 screws holding the exhaust duct cover in place (11/32” nutdriver). Remove the exhaust
duct cover by sliding it up and off the studs (the gasket will remain in place).
4. Clean the exhaust blower with a bottle brush or vacuum.
NOTE: Take care to prevent damaging the combustion blower impellers.
Advertising