Changing the TSTAT Program

This heater comes with three TSTAT programs built in. Each program is unique and allows you to modify
your thermostat setting to your preference. The insert is shipped pre-programmed in TSTAT program 1.

How to Tell Which TSTAT Program You Are In

When you press the “STOP” and “TSTAT” button simultaneously while the unit is cold the blue Auto-Fan
LED light will flash. It will flash once for Program 1, twice for Program 2, and three times for Program 3.

Switching Between Program 1, 2, and 3

Each time you press the “STOP” and “TSTAT” button simultaneously while the unit is cold, the TSTAT
program will toggle to the next program. Continue to press these two buttons until the blue Auto-Fan LED
light flashes the program you wish to use.

Thermostat Program 1

When the thermostat stops calling for heat (the thermostat is open) the thermostat “steps down” to a
lower heat setting. The heater will stay at this setting for 15 minutes. If the thermostat does not call for
heat, the thermostat will “step down” again to a lower setting (or off). At any time if the thermostat calls
for heat (thermostat is closed) during this cycle, the heater will resume at the HEAT output setting set at
the control board.

Heater Set at

HIGH

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set
on control panel dial.

If thermostat stops calling for heat (thermostat
open)

Heater goes to MEDIUM. If after 15 minutes
thermostat still open, heater goes to MEDIUM-
LOW. If after 15 minutes thermostat still open,
heater goes to LOW. If after 15 minutes
thermostat still open, heater turns off.

Heater Set at

MEDIUM

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set
on control panel dial.

If thermostat stops calling for heat (thermostat
open)

Heater goes to MEDIUM-LOW. If after 15
minutes thermostat still open, heater goes to
LOW. If after 15 minutes thermostat still open,
heater turns off.

Heater Set at

MEDIUM-LOW

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set
on control panel dial.

If thermostat stops calling for heat (thermostat
open)

Heater goes to LOW. If after 15 minutes
thermostat still open, heater turns off.

Heater Set at

LOW

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set
on control panel dial.

If thermostat stops calling for heat (thermostat
open)

Heater will run for 15 minutes. If thermostat still
open, heater turns off.

NOTE: This program is not recommended for areas with little heating requirements (mild climates,
small rooms, etc.).