Installation, For qualified installers only), Planning the installation – Avalon Firestyles AGP Pellet User Manual

Page 9: Minimum fireplace size, Fireplace damper

Advertising
background image

Installation

(For Qualified Installers Only)

9

© Travis Industries

4141230

100-01341

Planning the Installation

HINT:

Have an authorized Travis Industries dealer install this heater. If you install the
heater yourself, have your dealer review your installation plans.

HINT:

Inspect the chimney and clean as necessary before installing the heater. NOTE: The
convection blower is open to the fireplace cavity and may circulate odors from the
fireplace. You may wish to paint the interior of the fireplace with latex paint to
prevent odors from entering the home.

Minimum Fireplace Size

Fireplace Damper

Any existing damper must be removed or locked in the open position.

Min. 33.25" (845mm)
(includes circuit board)

Min. 21"

(534mm)*

Mantel
(combustible or non-combustible)

Min. 36.75" (934mm)

6" (153mm) from hopper lid

Non-Combustible Hearth

(Spark Protection Only)

Min. 14.25"

(362mm)

Min. 36" (915mm)

*Hopper Cover may be raised to 24"
(610mm) to accommodate a larger hopper.

Min. 16" (407mm)

6" (153mm) from firebox front

Min. 21.75" (553mm)