BECKHOFF FC5101 User Manual

Page 65

Advertising
background image

Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149

65

6: Toggling missed several times and guarding activated

Bits 5-15:

Associated COB ID

Offset 6:

Bits 0-7:

1: Incorrect value during SDO upload

2: Incorrect length during SDO upload

3: Abort during SDO up/download

4: Incorrect date during a boot-up message

5: Timeout while waiting for a boot-up message

Offset 7:

Bits 0-7:

2: Incorrect SDO command specifier

3: SDO toggle bit has not changed

4: SDO length too great

5:

SDO-Abort

6:

SDO-Timeout

Offset 8,9

Bits 0-7:

SDO up/download index

Offset 10:

Bits 0-7:

SDO up/download sub-index

Offset 11:

Bits 0-7:

reserved

Offset 12:

Bits 0-7:

Abort errorClass

Offset 13:

Bits 0-7:

Abort errorCode

Offset 14,15:

Bits 0-15:

Abort additionalCode

Offset 16-19:

Read value (if offset 6 = 1)

Offset 20-23:

Expected value (if offset 6 = 1)

Offset 24-25:

Number of consecutive emergencies

Offset 26 - n:

Emergencies (8 bytes each)