7.9.3

Wall-mounted

Programmable

keyboard

DEFINE_DEVICE

CRNET_RELAY= N:6:RELAY;
//define relay with the ID number of 6
CRNET_WallBoard

= N:9:WM;

//define

the wall-mounted programmable keyboard with
the ID of 9

DEFINE_EVENT

//

the

wall-mounted

programmable

keyboard’s (CRNET_WallBoard) first way return
data is to control ON/OFF of the relay:
CRNET_RELAY

//correspond to the DATA of the wall-mounted

programmable control keyboard. Data[0]==1
means being pressed down; == 0 means
bouncing back; DATA. Data is the returned
character array.

DATA_EVENT(CRNET_WallBoard,1)
{

ONDATA()
{

TRACE(“recive

data

from

zhu

gong”);

//////DATA.

Data

is

returned

character array from the com port//Note: currently

doesn’t support 0x8 display

if(DATA. Data[0]==1)
{

ON_RELAY(CRNET_RELAY,1);

//ON_VOL(CRNET_VOL_01);

//SET_VOLTOTOL(CRNET_VOL_01,”56666

”);

}

else if(DATA. Data[0]==0)
{

OFF_RELAY(CRNET_RELAY,1);

}

}

}

//same as above, the 2

nd

way

DATA_EVENT(CRNET_WallBoard,2)
{

ONDATA()
{

TRACE(“receive data from zhu

gong”);

//DATA. Data is the returned data

from the COM interface, displayed in
character array. Note: 0x8 is not
supported currently

if(DATA. Data[0]==1)
{

ON_RELAY(CRNET_RELAY,2);

//ON_VOL(CRNET_VOL_01);

//SET_VOLTOTOL(CRNET_VOL_01,”56666

”);

}
else if(DATA. Data[0]==0)
{

OFF_RELAY(CRNET_RELAY,2);

}

}

}

//same as above, 3

rd

way

DATA_EVENT(CRNET_WallBoard,3)
{

ONDATA()
{

TRACE(“recive

data

from

zhu

gong”);

//DATA. Data is the

returned data from the COM interface,

Advertising