Daktronics Matrix Displays with Colorado Timing Systems

13

5. Test Communications.

From the Venus 7000 shell, click the Diagnostics
RTD tab, select the Input created and click
Template View. In SwimDive Request II, select
Start List for Request Type and click Request.
Information should come across in Template
View. If not, check settings.

TimerInterface 2000 Settings

1. On the main menu of the Timer Interface 2000

program (Figure 16), click Add under the
INPUTS: section.

2. The Configure Input: window will open

(Figure 17).

Under the Select Timer: select Colorado Timer
(Figure 18). Under Select Port: click Edit.

3. The Enter Port Parameters window will

open (Figure 19).

Type the name of the input. For example: CTS
#1.
Under Port Type: Select COM Port (Figure
20
)
.

Select the Port that the timer is connected to and
configure the settings as follows:

Baud: 9600

Parity: Even

Data Bits: 8

Stop Bits: 2

4. Click OK and the note shown in Figure 21 will

appear. Click OK. After configuring an input,
shut down the TimerInterface 2000 program and
then re-start it for all of the settings to take
effect.

Figure 16: TimerInterface 2000

Figure 17: Configure Input

Figure 18: Select Timer

Figure 19: Enter Port Parameters

Figure 20: Com Port Settings

Figure 21: Timer Interface Notification