Timer interface 2000 settings – Daktronics Aquatics Interface with Daktronics Matrix Displays User Manual

Page 21

Advertising
background image

Daktronics Matrix Displays with Colorado Timing Systems

17

Timer Interface 2000 Settings

1. From the main menu of the Timer Interface 2000 program (Figure 16), click Add under

the INPUTS: section.

The Configure Input: window will open (Figure 17).

2. Under the Select Timer: select Colorado Timer (Figure 18).

Under Select Port: click Edit.

3. The Enter Port Parameters window will open (Figure 19).

Type the name of the input. For example, CTS #1.

Under Port Type: Select COM Port.

Select the Com Port that the timer is connected to and configure the Baud to 9600, Parity
to Even, Data Bits to 8 and Stop Bits to 2.

4. Click OK and the note shown in Figure 21 will appear. Click OK. After configuring an

input, shut down the TimerInterface 2000 program and then re-start it for all of the
settings to take effect.

5. After opening the Timer Interface

2000 program again, click Add
under the OUTPUTS: section
(Figure 22).

6. The Configure Output: window

will open (Figure 33).

Under Select Input: select the
previously configured input to
receive the data. (Example: 1:CTS
#1 – Com1,9600,8,Even)

Under the Select Output Type:
select Venus Enhanced RTD.
Next, click Edit under Select Port.

7. The Enter Port Parameters

window will open (Figure 34).

Type the name of the output.
(Example: CTS #1)

Figure 33: Configure Output:

Figure 34: Enter Port Parameters

Advertising