Hello, Zero – Digi-Star EZ 3200/EZ 3200V/EZ 3200V RC User Manual

Page 12

Advertising
background image

Digi-Star Model EZ3200/EZ3200V/EZ3200V RC

6. System operation

9

! copyright - 10/24/2001

6. System operation

!

EZ3200 V shown - EZ3200 and ES3200V RC operations are the same.

!

LB and KG annunciators are located along right hand edge of the 3200V display.

TURNING ON THE SCALE

Press

.

A brief message will be displayed (such as HELLO).

The scale then enters the GROSS weighing mode.

GROSS mode displays the weight change since the
unit was last ZERO/BALANCED.

Pressing

a second time during normal system

operation starts the self test.

TURNING OFF THE SCALE

Press

.

TO ZERO BALANCE THE SCALE

Press

and then within three seconds, press

.

The [Zero] key will "balance off" empty trailer, bin,
or platform weight.

The message ZERO is displayed to show completion of

the step and the scale is placed in the GROSS
mode.

Pressing only

will cause the message: TO

ZERO/BALANCE PRESS NET/ GROSS - THEN ZERO to be

displayed.

If the supply power is below the low battery threshold (10.5 Volts), the message CANNOT balance --
LOW BATTERY VOLTAGE is displayed. The message LO BAT will be periodically shown on the display

(approx. every five seconds) to alert the operator of the low battery condition.

Loss of power does not affect the Zero/Balance or Setup/Calibration values.

HELLO