! copyright - 10/24/2001
WEIGH AVERAGING
1. Press
to assign the RM operation to the
[Function] key.
2. Press
twice within three seconds to
perform the weigh averaging operation.
The COUNT or number of weight values added to the
weigh memory will be displayed first. Then the
message AVERAG is displayed, followed by the
average weight value.
3. To print the average weight value, press
while the average weight is still displayed.
BLACK OUT
!
The Clock Option is required as part of the Black Out option. The Clock records the time,
date, and preset remaining before the power outage (blackout).
The Black Out option is a preset enhancement that maintains the “preset amount left to go” in
non-volatile, permanent memory. This insures that the correct weight can be delivered even after
a power outage.
For example, a system loaded with 2000 lbs unloads a preset of 100 lbs. After unloading the first
500 lbs, a power outage occurs. When the power is restored and the scale turned back On, the
message POWER OUTAGE – PRESS START ON CONTROL BOX TO FINISH PRESET – CLEAR TO CANCEL MO/DA/UR 12:00A. At
this time, press START on the control box (or press the NET/GROSS key on the indicator). This
loads the preset amount remaining before the black out (500 lbs in this example).
Pressing
cancels the preset and the scale displays the GROSS weight.