Digi-Star Model EZ3200/EZ3200V/EZ3200V RC

7. Optional features

35

! copyright - 10/24/2001

WEIGH AVERAGING

1. Press

to assign the RM operation to the

[Function] key.

2. Press

twice within three seconds to

perform the weigh averaging operation.

The COUNT or number of weight values added to the

weigh memory will be displayed first. Then the

message AVERAG is displayed, followed by the

average weight value.

3. To print the average weight value, press

while the average weight is still displayed.

BLACK OUT

!

The Clock Option is required as part of the Black Out option. The Clock records the time,
date, and preset remaining before the power outage (blackout).

The Black Out option is a preset enhancement that maintains the “preset amount left to go” in
non-volatile, permanent memory. This insures that the correct weight can be delivered even after
a power outage.

For example, a system loaded with 2000 lbs unloads a preset of 100 lbs. After unloading the first
500 lbs, a power outage occurs. When the power is restored and the scale turned back On, the

message POWER OUTAGE – PRESS START ON CONTROL BOX TO FINISH PRESET – CLEAR TO CANCEL MO/DA/UR 12:00A. At

this time, press START on the control box (or press the NET/GROSS key on the indicator). This
loads the preset amount remaining before the black out (500 lbs in this example).

Pressing

cancels the preset and the scale displays the GROSS weight.