TO USE THE PRE-ALARM

The Pre-Alarm feature is an "early warning" for
the preset. For example, if the Pre-Alarm is set for
Weight with a value of 100 and the preset is 1000,
the preset alarm will flash during the last 100
lbs/kgs of the preset. The Pre-Alarm can also be set
to activate at a percentage of the preset instead of
a specific weight value. The alarms are continuous
once the preset is active. A Pre-Alarm provides an
early warning before reaching the preset which
allows the operator to be more accurate.

TO CHANGE THE PRE-ALARM VALUE

1. Go to Menu 4 of the Long Form Setup and

locate the P-MTHD Feature (see page 14:

To

enter the Long Form Setup

).

2. Press

to select either weight or percnt. The

indicator will flash the CAL annunciator.

3. Press

to store the setting. The Pre-Alarm

Feature (p-alm) is displayed next.

4. Press

to erase the current weight value.

The [Clear] key erases one digit at a time.

Continue to press the [Clear] key until 0 (zero)

is displayed.

5. Use the numeric keypad to enter a Pre-Alarm

Weight.

"""""!"

Set the pre-alarm value to 0 (zero) to

prevent the alarm output from pulsing!

6. Press

to store the setting.

7. Press and hold

and then press

to

return to normal Weighing Mode.

100

p mthd

5

2

5

3/6

4

Advertising