Toler – Digi-Star EZ 3200/EZ 3200V/EZ 3200V RC User Manual

Page 27

Advertising
background image

Digi-Star Model EZ3200/EZ3200V/EZ3200V RC

6. System operation

24

! copyright - 10/24/2001

USING THE AUTO ADVANCE FEATURE

The auto advance feature allows for hands free operation of programmed recipes. When the auto
advance feature is activated, the indicator automatically prints and advances to the next
ingredient once the Motion, Tolerance, and Delay Time requirements have been met. Motion,
tolerance, and delay time requirements are explained below.

The Tolerance feature is a “tolerance window” for the preset ingredient during batching. For
example, if the tolerance is set to 5% and the preset is 1000, the “tolerance window” is ±50. The
scale is in the “tolerance window” when the display is between 50 and -50.

The auto-advance circuitry of the recipe function activates the Delay Time counter while the
weight is in the tolerance window. The Delay Time allows the operator to slightly "under or over
shoot" an ingredient amount and still automatically advance to the next ingredient. The auto-
advance circuitry resets the Delay Time counter every time the weight moves out of the tolerance
window. If enabled, Motion Detection also resets the Delay Time Counter.

If the tolerance for that ingredient is exceeded, the message

OVER

is displayed alternately with the

weight value. If this occurs, the scale will not auto-advance until the excess weight is removed.
If the operator determines that the additional weight for that ingredient is acceptable, pressing

or

will advance to the next ingredient.

If the tolerance is set to

OFF

, the scale will always auto-advance after the ingredient amount has

been loaded regardless of any additional weight.

TO CHANGE THE TOLERANCE

1. Go to Menu 4 of the Long Form Setup and

choose

TOLER

(see page 14:

To enter the Long

Form Setup

).

2. Press

to choose the amount (by

percentage) that an ingredient can be
under/over-loaded and still automatically
advance.

Tolerance Percentage Settings
OFF, 0.5, 1, 2, 3, 4, 5, 7, or 10

!"

Set to OFF to always advance after the

ingredient amount has been reached.

3. Press

to store the setting.

4. Press and hold

and then press

to

return to normal Weighing Mode.

toler

3

2

Advertising