7. Use the numeric keypad to select the four digit
ingredient value.
8. Press
to enter the value.
The scale will display the message
STORED
indicating that the ingredient has been saved into
non-volatile memory.
9. Continue steps 5 through 8 until all
ingredients have been entered.
10. Press
to complete the recipe. The scale
will now calculate and display the
TOTAL
value
of the recipe.
11. Repeat steps 1 trough 10 until all recipes have
been programmed.
12. Press
to exit the Recipe Programming
Mode and enter Weighing Modes.
TO CHANGE THE ENTRY METHOD
1. In Menu 4 of the Long Form Setup, select E
MTHD. (see page 14:
To enter the Long Form
Setup
).
2. Press
. The indicator will beep, flash the
CAL annunciator and display the message E-
MTHD followed by the number 1, 2 or 3.
3. Press
again if you want to change the
Entry Method.
1 = Amount per Animal
2 = Percent (%) per Load
3 = Amount per Load
4. Press
to sore the setting.
5. Press and hold
and then press
to
return to normal Weighing Mode.