Grounding instructions – MicroE Mercury II 6000V User Manual

Page 15

Advertising
background image

Page 15

Section C - Reference

Grounding Instructions -

Mercury

II

6000

Sensor mounted to a surface that is
grounded through bearings or a poorly-
grounded surface, or mounted to a non-
conducting surface

C

C1

1..2

2..1

1

15-pin D-sub connector grounding: The
encoder's connector shell must be in intimate,
electrically conductive contact with the
customer-supplied mating connector, which
must be connected to the controller's ground.
If a customer-supplied shielded cable
connects the encoder to the controller, then
the outer shield on the customer-supplied
cable must be connected to the controller's
ground. The controller must be grounded to
earth at the point of installation.

C

C1

1..2

2..2

2

The encoder sensor must be mounted so that
it is electrically isolated from ground.

5 Volts

0 Volts

POWER

SUPPLY