Section B - Sensor Head Installation, Alignment and Calibration

B2.2

MII6000 Pushbutton Setup -
Setup / Calibration -

Linear Scales, or Rotary

Scales Used in Applications <360°

Setup / calibration must be performed whenever
the sensor is moved or the scale is replaced.

N

No

ottee:: a

allll p

prro

occeed

duurreess b

beello

ow

w m

muusstt b

bee p

peerrffo

orrm

meed

d a

att

≤≤11m

m/

/ss rreella

attiivvee m

mo

ottiio

onn b

beettw

weeeenn tthhee sseennsso

orr a

annd

d tthhee

sscca

allee..

B

B2

2..2

2..1

1

To start calibration, push and hold the Cal.
button for about two seconds – until the
Power/Cal. LED starts blinking slowly.

B

B2

2..2

2..2

2

Move the sensor 50mm to perform Gain /
Offset / Phase calibration. Move the sensor
back and forth if your scale has <50mm of
measuring length. After calibration both
limit LED’s come on steady.

B

B2

2..2

2..3

3

Move the sensor to an area of the scale
away from the index and limit markers.
Push the Cal. button once quickly. The
Power/Cal. LED will start blinking quickly.

B

B2

2..2

2..4

4

Move the sensor over the index up to 20
passes (one pass is a cycle back and
forth). The Left Limit LED will start blinking
quickly. (Note: if the sensor is positioned
over the left limit marker, the Left Limit LED
will come on steady).

B

B2

2..2

2..5

5

Move the sensor over the left limit marker

Setup and Calibration -

Mercury

II

6000 Models – Pushbutton Setup

and press the Cal. button once quickly.
The Right Limit LED will start blinking.
(Note: if the sensor is positioned over the
right limit marker, the Right Limit LED will
come on steady.)

B

B2

2..2

2..6

6

Move the sensor over the right limit
marker and press the Cal. button once
quickly. All LED’s will flash together twice
to indicate that setup is completed.

B

B2

2..2

2..7

7

The encoder is now ready for connection
to the controller for use in servo control.

N

No

ottee:: tto

o sskkiip

p a

annyy p

po

orrttiio

onn o

off tthhiiss cca

alliib

brra

attiio

onn a

annd

d a

annd

d m

mo

ovvee o

onn tto

o tthhee nneexxtt p

po

orrttiio

onn,, p

puusshh a

annd

d hho

olld

d tthhee C

Ca

all.. b

buutttto

onn

ffo

orr ttw

wo

o sseecco

onnd

dss..

Note:

Calibration of the left and right limits should always
be performed while “Limit Polarity” is in the “Limits
Normal” mode. This mode is set in the “Calibration
and Align” tab of SmartPrecision

II

Software.